Y-700 Automatic Transfer Switch Controller

Programmable output relay capacity: 10A 277VAC passive output
                                                                                 10A 250VAC passive output

EMC test criteria: Complies with GB/T 14048.11-2024 and IEC/EN 60947-6-1
Outline dimension: 260mm*180mm*55mm
Pore size :167mm*236mm
Working temperature: (-20~+70)℃
Working humidity:(20~93)%RH
Storage temperature: (-30~+80)°℃
Levels of protection :IP20
Weight: About 1 kg

rEAD more
宇煌 Y-800型 母联控制器 左侧 英文
The Y-800 busbar controller is used to control three frame circuit breakers, realize the conversion of two power supplies and the busbar connection on the load side.It is based on microprocessor, which can detect the voltage of two three-phase incoming lines accurately, make accurate judgment on the voltage abnormality (overvoltage, undervoltage, over frequency, under frequency, missing phase, reverse phase sequence), complete the power conversion and the connection and disconnection of the bus on the load side according to the given logic, and output the passive control switch to complete the control of the load, display the system status and other functions.The controller is equipped with electrical interlock accessories, which cooperate with mechanical interlock to realize redundant interlock system and improve the reliability of operation.The product has compact structure, simple wiring and high reliability. It can be widely used in electrical automatic control systems of power, telecommunications, petrochemical, mining, rail transit, municipal, data center, intelligent building and other industries.

Model Description

企业微信截图_17665650816542

Main Technical Parameters

Project description
Working voltage 1.B+and B-terminals:DC(12-60V);2.AC power supply(90-305V)
Power consumption <6W
AC input voltage Altematine current sy-sten
Three-phase four-wire(L-L) (80~625)V
Three-phase three-wire(L-L) (80~625)V
Single phase two-wire(L-N) (50~360)V
Two-phase three-wire(L-L) (80~625)V
Voltage resolution:1V Accuracy:2%
a-c cycle Rated:50/60Hz;Range:15Hz-75Hz;
Resolution:0.1Hz;Precision:0.1Hz
Programmable output relay capacity 10A 277VAC passive output
10A 250VAC passive output
RS485 interface Isolated half-duplex mode with configurable baud rates of 2400,4800,9600,and 19200.
The Modbus-RTU communication protocol supports a maximum transmission distance of 1000 meters.
EMC test criteria Complies with GB/T 14048.11-2024 and IEC/EN 60947-6-1
Outline dimension 260mm*180mm*55mm
Pore size 167mm*236mm
Working temperature (-20~+70)℃
Working humidity (20~93)%RH
Storage temperature (-30~+80)°℃
Levels of protection IP20
Weight About 1kg

 