Leave Your Message
Products Categories
Featured Products

LMS1-N Automatic Transfer Switch 250A ATS - High-Quality China Supplier & Factory Models Available

Model Name: LMS1-N

,

Rated Voltage: AC230V, AC400V

,

Rated Current: 16~630A

,

Pole: 2P, 3P, 4P

,

Product Category: PC Class

,

Features: 2 Position, No Controller

,

Drive Mode: Excitation Type

,

Certification: CE, CB, CCC

,

Standard: IEC 60947-6-1

,

Email: sale@lvma-ele.com

,

Looking for high-quality electrical solutions? Our LMS1-N model offers reliable performance with a rated voltage of AC230V and AC400V. Designed for rated currents ranging from 16 to 630A, this versatile device comes in 2P, 3P, and 4P options. With its PC Class compatibility and exciting features such as 2 Position functionality without a controller, it's suitable for various applications. Certified by CE, CB, and CCC, our product adheres to the IEC 60947-6-1 standard, ensuring safety and reliability. As a trusted factory and suppliers in China, we pride ourselves on delivering exceptional products. For inquiries, please contact us at sale@lvma-ele.com.

    LMS1-LA Series Manual

    LMS1-LA as our ingenuity research and development of a new generation of dual power automatic transfer switch, in the performance and technology to achieve a major breakthrough. The product provides 63A, 125A, 250A, 400A, 630A and other rated current specifications, whether it is the continuous operation of massive servers in data centers, or the uninterrupted power supply of life support equipment in hospital ICU wards, the stable operation of elevator and fire fighting system in high-rise buildings can fully meet the power demand in different scenarios. ​

    Its switching speed can be called industry-leading, switching time only 10ms-50ms, with millisecond response speed to complete power conversion. In the data center, the LMS1-LA automatic transfer switch can switch to the standby power supply in a very short period of time in the face of sudden power failure, avoiding data loss and system collapse caused by momentary power failure; in the hospital environment, the LMS1-LA automatic transfer switch can switch to the standby power supply in a very short period of time, millisecond-level power switching can guarantee the stable operation of precision instruments and first-aid equipment in operating rooms, and escort the safety of patients. When applied to high-rise buildings, fast power changeover ensures smooth parking of elevators, normal operation of fire fighting systems and improved building Factor of safety. ​
    The transfer switch is composed of a high performance excitation contactor and an intelligent controller. When working, the electromagnetic coil produces a strong and stable attraction to drive the switching action to ensure the instant completion of power switching. This feature not only effectively guarantees the rapid switching of the power supply when the equipment is powered off, but also realizes the seamless connection of the power supply, which provides a reliable and solid power guarantee for the equipment with strict requirements for power continuity. ​

    Model Description

    ats-250a

    Main Technical Parameters

    Model Name LMS1-32N LMS1-63N LMS1-125N LMS1-250N LMS1-400N LMS1-630N
    Rated insulation voltage (Ui) AC 690V
    Rated working voltage (Ue) AC 400V
    Rated working current (Ie) 16, 20, 25, 32 40, 53, 63 80, 100, 125 160, 180, 200, 225, 250 315, 400 500, 630
    Rated concussion withstand voltage (Uimp) 8kV
    Rated control current (A) 5 7
    Using category AC-33B
    Kind of throw Double throw
    Poles 2P / 3P / 4P 2P / 3P / 4P 2P / 3P / 4P 3P / 4P 3P / 4P 3P / 4P
    Service life Mechanical 20,000 17,000
    Electric 6,000 6,000

    LMS1-N Type ATS Electrical Schematic Diagram

    ats-250a-1
    ⚠️ Note: In the absence of a dedicated ATS controller, the two power sources in the controller circuit can not be simultaneously energized.

    Structure and Mounting Dimensions

    automatic-transfer-switch-ats-5automatic-transfer-switch-ats-1-3
    automatic-transfer-switch-ats-2-1automatic-transfer-switch-ats-3-1
    Frequently Asked Questions (FAQ)
    Q What is the rated working voltage of the LMS1-N series ATS?
    The rated working voltage (Ue) of the LMS1-N series Automatic Transfer Switch is AC 400V, while the rated insulation voltage (Ui) is AC 690V, ensuring safe and reliable operation in standard industrial and commercial power systems.
    Q What current ratings are available for the LMS1-N series?
    The LMS1-N series covers a wide range of rated working currents (Ie): LMS1-32N (16–32A), LMS1-63N (40–63A), LMS1-125N (80–125A), LMS1-250N (160–250A), LMS1-400N (315–400A), and LMS1-630N (500–630A), accommodating various load requirements.
    Q What pole configurations are available for the LMS1-N ATS?
    The LMS1-32N, LMS1-63N, and LMS1-125N models are available in 2P, 3P, and 4P configurations. The LMS1-250N, LMS1-400N, and LMS1-630N models are available in 3P and 4P configurations, making them suitable for both single-phase and three-phase power systems.
    Q What is the service life of the LMS1-N series ATS?
    For the LMS1-32N to LMS1-250N models, the mechanical service life is 20,000 operations and the electrical service life is 6,000 operations. For the LMS1-400N and LMS1-630N models, the mechanical service life is 17,000 operations and the electrical service life is 6,000 operations.
    Q Can both power sources in the ATS controller circuit be energized simultaneously?
    No. In the absence of a dedicated ATS controller, the two power sources in the controller circuit cannot be simultaneously energized. This is a critical safety requirement to prevent backfeed and protect connected equipment and personnel.
    Q What is the using category and kind of throw for the LMS1-N ATS?
    The LMS1-N series ATS is classified under using category AC-33B, which is suitable for switching motor loads and other general-purpose AC loads. It operates as a double throw switch, ensuring a seamless and safe transfer between the main power supply and the backup/generator source.

    Leave Your Message