LMS1-LA Series 100A Automatic Transfer Switch ATS - Certified China Suppliers & Factory

Model Name: LMS1-LA

,

Rated Voltage: AC230V, AC400V

,

Rated Current: 16A-630A

,

Poles: 2P, 3P, 4P

,

Product Category: PC Class

,

Rank Current Options: 63A, 100A, 250A, 630A

,

Features: 2 Position Configuration

,

Drive Mode: Excitation Type

,

Certifications: CE, CB, CCC

,

Standards Compliance: IEC 60947-6-1

,

Contact Us: sale@lvma-ele.com

,

As a leading supplier and factory in China, we proudly offer the LMS1-LA model, designed for both versatility and efficiency. With rated voltages up to AC400V and a wide range of rated currents, our product meets various industrial needs. Available in multiple pole configurations and featuring a robust design, the LMS1-LA ensures reliable performance and compliance with international standards.

    LMS1-LA Series Manual

    LMS1-LA as our ingenuity research and development of a new generation of dual power automatic transfer switch, in the performance and technology to achieve a major breakthrough. The product provides 63A, 125A, 250A, 400A, 630A and other rated current specifications, whether it is the continuous operation of massive servers in data centers, or the uninterrupted power supply of life support equipment in hospital ICU wards, the stable operation of elevator and fire fighting system in high-rise buildings can fully meet the power demand in different scenarios. ​

    Its switching speed can be called industry-leading, switching time only 10ms-50ms, with millisecond response speed to complete power conversion. In the data center, the LMS1-LA automatic transfer switch can switch to the standby power supply in a very short period of time in the face of sudden power failure, avoiding data loss and system collapse caused by momentary power failure; in the hospital environment, the LMS1-LA automatic transfer switch can switch to the standby power supply in a very short period of time, millisecond-level power switching can guarantee the stable operation of precision instruments and first-aid equipment in operating rooms, and escort the safety of patients. When applied to high-rise buildings, fast power changeover ensures smooth parking of elevators, normal operation of fire fighting systems and improved building Factor of safety. ​
    The transfer switch is composed of a high performance excitation contactor and an intelligent controller. When working, the electromagnetic coil produces a strong and stable attraction to drive the switching action to ensure the instant completion of power switching. This feature not only effectively guarantees the rapid switching of the power supply when the equipment is powered off, but also realizes the seamless connection of the power supply, which provides a reliable and solid power guarantee for the equipment with strict requirements for power continuity. ​

    Model Description

    Notice:
    • Separated type ATS can be chose Y-701(LED) or Y-702(LCD) Controller.
    • ATS without output signal to start generator, Y-701 and Y-702 controller with it.
    • Working mode depends on the setting of controller, two position LA type ATS only available for self-input and self-recover.

    Working Environment

    ✓
    Ambient air temperature: ambient temperature -5℃ to +40℃, and the 24-hour average temperature value does not exceed Over +35°C. Users whose ambient air temperature is higher than +40°C or lower than -5°C should consult with the manufacturer.
    ✓
    The highest temperature of atmospheric humidity: when the degree is +40℃, the relative humidity does not exceed 50%, and the maximum relative humidity per month Degree 90%, resistant to the influence of humid air on the sea, and can allow higher relative humidity at lower temperatures, special measures should be taken for the occasional condensation caused by temperature changes.
    ✓
    Installation altitude: The altitude of the installation site does not exceed 2000 meters. When used at higher altitudes, the dielectric strength and cooling effect of the air should be considered to be reduced, please consult with the manufacturer.
    ✓
    Pollution level: The environmental pollution level of the installation site is level 3.
    ✓
    Installation category: IV.
    ✓
    Installation inclination: the product is fixedly installed in the cabinet, the maximum inclination is ±22.5°.
    ✓
    Arcing distance: The arcing distance is 30mm when AC 400V. The arcing distance when AC 690V is 60mm.

    Main Technical Parameters

    Model LMS1-LA
    Insulation voltage AC 690V
    Rated voltage AC 400V
    Rated current 20A~125A 160A~250A 315A~630A
    Rated impulse withstand voltage 8kV
    Kind of throw Double throw
    Wiring method Front board
    Short-time resistance current 10kA
    Through to breaking capacity 17kA
    Transfer time A Power Input 80ms 80ms 100ms
    Break 30ms 30ms 30ms
    B Power Input 100ms 100ms 120ms
    Break 30ms 30ms 30ms
    Electrical Life 1000 1000
    Mechanical Life 5000 4000
    Use type AC-33ib
    Accessaries Manual handle

    Structure and Mounting Dimensions

    Frequently Asked Questions (FAQ)

    What controllers can be selected for the separated type ATS?
    You can choose either the Y-701 (LED) or the Y-702 (LCD) Controller for the separated type ATS.
    Does the ATS include an output signal to start a generator?
    The standard ATS does not come with an output signal to start a generator. However, the Y-701 and Y-702 controllers are equipped with this generator start signal feature.
    What are the ambient temperature requirements for operation?
    The ambient air temperature should range between -5℃ and +40℃, with the 24-hour average temperature not exceeding +35°C. For temperatures outside this range, please consult the manufacturer.
    What is the maximum installation altitude for this switch?
    The standard installation altitude should not exceed 2000 meters. If using at higher altitudes, you must account for reduced dielectric strength and cooling effects of the air, and consult with the manufacturer.
    What is the typical transfer time for the LMS1-LA model?
    For A Power, the input time is 80ms to 100ms and the break time is 30ms. For B Power, the input time is 100ms to 120ms and the break time is 30ms.
    What are the electrical and mechanical lifespans of the switch?
    The LMS1-LA switch has an electrical life of 1000 cycles. The mechanical life is 5000 cycles for lower current ratings and 4000 cycles for higher ratings (315A~630A).