Leave Your Message
Products Categories
Featured Products

China LMS1-SA Series 630A Automatic Transfer Switch ATS - Reliable Suppliers & Factory Direct Solutions

,

Model Name: LMS1-SA

,

Rated Working Voltage: AC230V, AC400V

,

Rated Working Current: 16A to 630A

,

Pole Configuration: 2P, 3P, 4P

,

Product Category: PC Class

,

Available Current Ratings: 63A, 125A, 250A, 630A

,

Key Features: 3 Position, Built-in ATS Controller

,

Drive Mode: Excitation Type

,

Certifications: CE, CB, CCC

,

Standards Compliance: IEC 60947-6-1

,

If you are looking for reliable electrical solutions, contact us at our factory in China. As one of the leading suppliers, we are dedicated to providing high-quality products to meet your needs. For inquiries, please email us at sale@lvma-ele.com.

,
    LMS1-LA Series Manual

    LMS1-LA as our ingenuity research and development of a new generation of dual power automatic transfer switch, in the performance and technology to achieve a major breakthrough. The product provides 63A, 125A, 250A, 400A, 630A and other rated current specifications, whether it is the continuous operation of massive servers in data centers, or the uninterrupted power supply of life support equipment in hospital ICU wards, the stable operation of elevator and fire fighting system in high-rise buildings can fully meet the power demand in different scenarios. ​

    Its switching speed can be called industry-leading, switching time only 10ms-50ms, with millisecond response speed to complete power conversion. In the data center, the LMS1-LA automatic transfer switch can switch to the standby power supply in a very short period of time in the face of sudden power failure, avoiding data loss and system collapse caused by momentary power failure; in the hospital environment, the LMS1-LA automatic transfer switch can switch to the standby power supply in a very short period of time, millisecond-level power switching can guarantee the stable operation of precision instruments and first-aid equipment in operating rooms, and escort the safety of patients. When applied to high-rise buildings, fast power changeover ensures smooth parking of elevators, normal operation of fire fighting systems and improved building Factor of safety. ​
    The transfer switch is composed of a high performance excitation contactor and an intelligent controller. When working, the electromagnetic coil produces a strong and stable attraction to drive the switching action to ensure the instant completion of power switching. This feature not only effectively guarantees the rapid switching of the power supply when the equipment is powered off, but also realizes the seamless connection of the power supply, which provides a reliable and solid power guarantee for the equipment with strict requirements for power continuity. ​

    LMS1-SA is suitable for AC 400V and below, the rated frequency is 50Hz. In the power system, the controller and transfer switch can quickly transfer the load from the main power supply to the standby power supply when there is phase loss, overvoltage, etc.
    Model Description
    automatic-transfer-switch-1-1
    Main Technical Parameters
    Model Name LMS1-63SA LMS1-125SA LMS1-250SA LMS1-630SA
    Rated insulation voltage (Ui) AC 690V
    Rated working voltage (Ue) AC 230V (2P) / AC 400V
    Rated working current (Ie) 16~63A 20~125A 160~250A 315~630A
    Rated concussion withstand voltage (Uimp) 8kV 12kV 6kV
    Using category AC-33B AC-33iB
    Kind of throw Double throw
    Wiring method Front board
    Poles 2P 3P 4P 2P 3P 4P 2P 3P 4P 2P 3P 4P
    Performance Rated Short-time withstand current 5kA 10kA 12.6kA
    Rated operating short-circuit breaking capacity 8kA 25kA 30kA
    Electrical Life / Mechanical Life 6000/20000 1000/4000
    Structure and Mounting Dimensions
    on-1
    LMS1-SA Series PC Automatic transfer switch detail (2)
    automatic-transfer-switch-6
    LMS1-SA Series PC Automatic transfer switch detail (4)
    automatic-transfer-switch-4-4
    LMS1-SA Series PC Automatic transfer switch detail (1)
    • Start generator: When fault occurs in the normal power, this port will connect after delaying some time.
    • Fire-fighting: Connect the fire-fighting port, double disconnecting light is on, the ATS double disconnect. Remove the connection, push the automatic/manual pushbutton to reset.
    • Fire-fighting feedback: When ATS is in double-disconnecting state, the fire-fighting port connects.
    • Normal close: When the normal power of ATS is in closing state, closing signal without power is output from this port.
    • Standby close: When the standby power of ATS is in closing state, closing signal without power is output from this port.
    • Normal earth wire: When ATS are 3 phases, the normal earth wire is connected into this port.
    ?
    Frequently Asked Questions
    Q What is the rated voltage range for the LMS1-SA Automatic Transfer Switch?
    A The LMS1-SA series is suitable for AC 400V and below, with a rated working voltage of AC 230V (2P) or AC 400V, and a rated insulation voltage (Ui) of AC 690V. The rated frequency is 50Hz.
    Q What current ratings are available for the LMS1-SA series?
    A The LMS1-SA series covers a wide range of rated working currents: LMS1-63SA (16–63A), LMS1-125SA (20–125A), LMS1-250SA (160–250A), and LMS1-630SA (315–630A), making it suitable for various load requirements.
    Q How many poles are available for the LMS1-SA transfer switch?
    A The LMS1-SA series is available in 2P, 3P, and 4P configurations across all model variants, providing flexibility for single-phase and three-phase power systems.
    Q What is the electrical and mechanical life expectancy of the LMS1-SA ATS?
    A For the LMS1-63SA, LMS1-125SA, and LMS1-250SA models, the electrical life is 6,000 operations and mechanical life is 20,000 operations. For the LMS1-630SA model, the electrical life is 1,000 operations and mechanical life is 4,000 operations.
    Q Does the LMS1-SA support fire-fighting integration?
    A Yes. The LMS1-SA features a dedicated fire-fighting port. When connected, the double disconnecting indicator light turns on and the ATS enters double-disconnect mode. It also provides a fire-fighting feedback signal when the ATS is in the double-disconnecting state.
    Q What short-circuit breaking capacity does the LMS1-SA series offer?
    A The rated operating short-circuit breaking capacity varies by model: LMS1-63SA supports 8kA, LMS1-125SA and LMS1-250SA support 25kA, and LMS1-630SA supports 30kA, ensuring reliable protection under fault conditions.

    Leave Your Message